Fault Analysis and Handling of Otis MCS220 GEN-II Elevator Weighing Device

發(fā)布時:2024-06-12   來源:江西天虹機電有限公司   閱讀:2210

The earliest Otis GEN-II MCS220 elevator weighing system installed four weighing sensors and an LWB weighing board on the frame of the car floor. The weighing board was connected to the MCB-II board through CAN-BUS communication, and the four weighing sensors were used to obtain the weight analog voltage of passengers in the car. This allowed the GENG-II elevator to be given a reasonable pre torque when starting or stopping, providing good comfort when braking. When the comfort was abnormal, the service tool MCB-II board was tested, and the service tool error note M-2-2-1 was recorded. After pressing the shift+3 on the service tool, the following faults may occur


1. ALW: LWB Board


Possible reasons: internal errors or abnormalities in the weighing device board,


Solution: Replace the weighing device version LWB


2. ALW: Load Sensor


Possible causes of malfunction:


1) Detected at least one load cell malfunction or damage


Solution: Replace the weighing sensor


2) The GAIN data of the weighing device board is abnormal.


Solution: Perform GAIN correction adjustment


3) The output voltage of the sensor is abnormal, and the voltage is not between 2000 (2V-7V) millivolts and 7000 millivolts


Solution: Adjust the pressure of the weighing sensor to a suitable range of 2000 (2V-7V) millivolts to 7000 millivolts


3. ALW: CAN Bus


1) Fault cause, possible cause: communication loss between MCB-II board and LWB2 board


Solution: Check the connection of the CAN communication line


2) Abnormal power supply on LWB2 board


Solution: Check MCB P5:6- MCB P5:5 DC (+15V) (HL2)


3) MCB-II board damaged


Solution: Replace the MCB-II board.


?

版權所有?江西天虹機電有限公司  聯(lián)系人:19917177918  黃女士 座機:0797-8220752

QQ:2993817878  地址:江西省贛州市經濟技術開發(fā)區(qū)坪峰嶺路19-4號 技術支持:江西華邦LOGO白色.png

備案號:贛ICP備18014169號-1

掃碼打開手網

掃碼關注官方微信

?

Fault Analysis and Handling of Otis MCS220 GEN-II Elevator Weighing Device

2024-06-12

The earliest Otis GEN-II MCS220 elevator weighing system installed four weighing sensors and an LWB weighing board on the frame of the car floor. The weighing board was connected to the MCB-II board through CAN-BUS communication, and the four weighing sensors were used to obtain the weight analog voltage of passengers in the car. This allowed the GENG-II elevator to be given a reasonable pre torque when starting or stopping, providing good comfort when braking. When the comfort was abnormal, the service tool MCB-II board was tested, and the service tool error note M-2-2-1 was recorded. After pressing the shift+3 on the service tool, the following faults may occur


1. ALW: LWB Board


Possible reasons: internal errors or abnormalities in the weighing device board,


Solution: Replace the weighing device version LWB


2. ALW: Load Sensor


Possible causes of malfunction:


1) Detected at least one load cell malfunction or damage


Solution: Replace the weighing sensor


2) The GAIN data of the weighing device board is abnormal.


Solution: Perform GAIN correction adjustment


3) The output voltage of the sensor is abnormal, and the voltage is not between 2000 (2V-7V) millivolts and 7000 millivolts


Solution: Adjust the pressure of the weighing sensor to a suitable range of 2000 (2V-7V) millivolts to 7000 millivolts


3. ALW: CAN Bus


1) Fault cause, possible cause: communication loss between MCB-II board and LWB2 board


Solution: Check the connection of the CAN communication line


2) Abnormal power supply on LWB2 board


Solution: Check MCB P5:6- MCB P5:5 DC (+15V) (HL2)


3) MCB-II board damaged


Solution: Replace the MCB-II board.


?